Technical Information:
• Combines technologies: Single or Dual Wavelength UV-C Germicidal Oxidation and Germicidal Irradiation
• Services: 120 / 60 / 1. Uninterrupted supply – 24-hour operation required. High level
• 5 ft power cable to be connected to suitably isolated fused spur
• Voltage Directive (LVD) 2014/30/EU
• Electromagnetic Compatibility Directive (EMC) 2014/30/EU
• Tested and certified to UL 867:2011 Ed.5+R:07Aug2018, CSA C22.2#187:2020 Ed.5, UL 61010-1:2012 Ed.3+R:19Jul2019, IEC 60335-2-65-1:2002, COR1:2004, AMD1:2008, AMD2:2015 in conjunction with IEC 60335-1:2010, COR1:2010, COR2:2011, AMD1:2013, COR1:2014, AMD2:2016, COR1:2016
• Produced under the control of our comprehensive BSI ISO 9001:2015 Quality Management System (certificate FS 616985) and is pending an ETL listing through UL approval.
• Class ll certified for electrical insulation
• Click here for more Single Wavelength Specifications
• Click here for more Dual Wavelength Specifications
HyGenikx Air & Surface Sanitization System Dimensions
Height: 400 mm (15 ¾ inch)
Width: 135 mm (5 ¼ inch)
Depth: 110 mm (4 3/8 inch)
120 volt / 60 Hz / single phase
• HyGenikx Air & Surface Sanitization System Brochure – Dual Wave - Click here
• HyGenikx Air & Surface Sanitization System Brochure – Single Wave - Click here
• HyGenikx – How it Works Flyer - Click here
• Installation & Operating Manual - Click here